Skip to main content

Cast Resin Transformers

Other Transformers

Cast Resin transformers are supplied either in IP00 specification or in sheet steel ventilated enclosures complete with HV and LV cable boxes.

Cast resin transformers are a popular choice for use in commercial, industrial and residential sites. These power transformers require practically no maintenance and have a much lower environmental impact than traditional oil-immersed power transformers.

Cast Resin Transformers are Hazard free to the environment, extremely reliable and suitable for places where environmental issues and fire safety are major important factors.

Their Auto-extinguishing and various other safety features make it the obvious choice for indoor applications and other areas with high fire risk.

Range Availability

  • Distribution range from 50kVA to 4000kVA
  • Power range from 3000kVA to 16MVA
  • Primary voltages up to 36KV

We supply special Cast Resin Transformer units to suit most industrial applications.

AM Transformers is a global leader in the field of Electrical Power, dedicated to the provision of specialist services & products to the engineering industry in general and to the electrical power in particular. AM Transformers are also leading suppliers of 3 phase transformers in the UK.

If you would like more information on what we can provide you or if you have specific requirements for your Cast Resin Transformers then please request a quote with your details or get in touch via phone, we’re here to help!

Add to quote

12VA
DESCRIPTION: 12VA Chassis Mounting Transformer
PART NUMBERS : EI510, EI511, EI512, EI513, EI514
PRIMARY : 0 – 120V, 0 – 120V
SECONDARY : 6 +6V, 9 + 9V, 12 + 12V, 15 + 15V, 20 + 20V Insulation Test : 3750V Regulation : 16% Temperature range : -10 to 60 Deg C
Dimensions : 55 x 41 x 46mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973

20VA
DESCRIPTION : 20VA Chassis Mounting Transformer
PART NUMBERS : EM520, EM521, EM522, EM523, EM524, EM525
PRIMARY : 230V SECONDARY : 6V, 9V, 12V, 15V, 18V, 24V
Insulation Test : 3750V Regulation : 17% Temperature range : -10 to 60 Deg C
Dimensions : 60 x 46 x 50mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973.

25VA
DESCRIPTION : 25VA Chassis Mounting Transformer
PART NUMBERS : EN530, EN531, EN532, EN533, EN534
PRIMARY : 0 – 120V, 0 – 120V
SECONDARY : 6 +6V, 9 + 9V, 12 + 12V, 15 + 15V, 20 + 20V Insulation Test : 3750V Regulation : 10% Temperature range : -10 to 60 Deg C Dimensions : 69 x 52 x 58mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973.

50VA
DESCRIPTION : 50VA Chassis Mounting Transformer
PART NUMBERS : EP540, EP541, EP542, EP543, EP544
PRIMARY : 0 – 120V, 0 – 120V
SECONDARY : 6 +6V, 9 + 9V, 12 + 12V, 15 + 15V, 20 + 20V Insulation Test : 3750V Regulation : 9% Temperature range : -10 to 60 Deg C Dimensions : 79 x 58 x 65mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973

100VA
DESCRIPTION : 100VA Chassis Mounting Transformer
PART NUMBERS : ER550, ER551, ER552, ER553, ER554
PRIMARY : 0 – 120V, 0 – 120V
SECONDARY : 6 +6V, 9 + 9V, 12 + 12V, 15 + 15V, 20 + 20V Insulation Test : 3750V Regulation : 9% Temperature range : -10 to 60 Deg C Dimensions : 89 x 75 x 65mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973

200VA
DESCRIPTION : 200VA Chassis Mounting Transformer
PART NUMBERS : EU560, EU561, EU562, EU563, EU564
PRIMARY : 0 – 120V, 0 – 120V
SECONDARY : 6 +6V, 9 + 9V, 12 + 12V, 15 + 15V, 20 + 20V Insulation Test : 3750V Regulation : 5% Temperature range : -10 to 60 Deg C Dimensions : 101 x 85 x 85mm Standards : Designed to meet the insulation requirements of EN60742, VDE0551 and conforms with the provisions of the Low Voltage Directive of the Council of the European Communities of 19 Feb 1973

You may also like…

Single Phase Transformer 50 VA | AM Transformers

Single Phase Transformers

Single Phase Power Transformer 100VA

100VA Power transformers utilise alternating AC voltages, these come in different phases often singl...
Single Phase Transformer 50 VA | AM Transformers

Single Phase Transformers

Single Phase Power Transformer 50VA

50VA Power transformers utilise alternating AC voltages, these come in different phases often single...
Single Phase Transformer 10KVA | AM Transformers

Single Phase Transformers

Single Phase Custom Power Transformer

Custom Power transformers utilise alternating AC voltages, these come in different phases often sing...